Actions
bug #406
open0℃存储2h后主板开机,USB_OTG用数据线连上电脑无法投屏
Start date:
04/22/2026
Due date:
04/25/2026 (33 days late)
% Done:
0%
Estimated time:
Description
NYD_KYJYJ_001_V1.0 硬件测试申请
Files
Actions
Added by yongnan yu 2 months ago. Updated about 1 month ago.
0%
Description
NYD_KYJYJ_001_V1.0 硬件测试申请
Files
| NYD_KYJYJ_001_V1.0 硬件测试2026.04.10.xlsx (10.4 MB) NYD_KYJYJ_001_V1.0 硬件测试2026.04.10.xlsx | zc huang, 04/10/2026 09:56 AM | ||
| NYD_KYJYJ_001_V1.0 硬件测试2026.04.10.xlsx (10.4 MB) NYD_KYJYJ_001_V1.0 硬件测试2026.04.10.xlsx | yongnan yu, 04/16/2026 03:41 PM | ||
| NYD_KYJYJ_001_V1.0 硬件测试2026.04.20-回归测试.xlsx (10.6 MB) NYD_KYJYJ_001_V1.0 硬件测试2026.04.20-回归测试.xlsx | zc huang, 04/20/2026 09:47 AM | ||
| clipboard-202604221006-ma1vu.png (17.1 KB) clipboard-202604221006-ma1vu.png | yongnan yu, 04/22/2026 10:06 AM |
NYD_KYJYJ_001_V1.0硬件测试已完成,问题汇总如下:
1、待机功耗1.28W,标准为:0.1W
2、纹波:一个纹波偏高,一个电压异常
3、触摸屏测试:原理图标识J5200、J5400的电压与实测值不一致
4、屏时序:VCCI_2V8、IOVCC_1V8上电时序异常
5、低温-10℃:
5.1、-10℃存储2h后主板开机,USB_OTG用数据线连上电脑无法投屏进不了老化模式;
5.2、将板子取出来冷却5分钟左右上电一直开不了机,要等很久才能开机。
6、晶振:24.96PPM有点偏高。
申请复测
复测了FAIL项,1个问题未关闭,OTG低温0℃不能与电脑连接,只能识别鼠标。
低温0℃:
1、0℃存储2h后主板开机,USB_OTG用数据线连上电脑无法投屏;