Actions
bug #88
closed【H5PRO】【量产必解】【设置】【必现】在设置关闭按键音或者打开按键音,断电上电开机后,会与原先设置的开关相反,被打开或关闭(重启操作就正常)
Start date:
05/30/2025
Due date:
% Done:
0%
Estimated time:
Description
[软件版本]
h5p
user_S905X5M-20250530.img
链接: https://pan.baidu.com/s/1Jz37P0WjAczHdZDzBykY7w?pwd=65f5 提取码: 65f5
5.0.0.7
[前提条件]
[复现步骤]
1、在设置关闭按键音或者打开按键音,断电上电开机
[测试结果]
会与原先设置的开关相反,被打开或关闭(重启操作就正常)
[期望结果]
保存断电前设置的开关参数
[概率]
必现
Files
Updated by daquan huang 26 days ago
- Subject changed from 【H5PRO】【设置】【必现】在设置关闭按键音或者打开按键音,断电上电开机后,会与原先设置的开关相反,被打开或关闭 to 【H5PRO】【设置】【必现】在设置关闭按键音或者打开按键音,断电上电开机后,会与原先设置的开关相反,被打开或关闭(重启操作就正常)
- Description updated (diff)
Updated by wenjiao feng 22 days ago
- Subject changed from 【H5PRO】【设置】【必现】在设置关闭按键音或者打开按键音,断电上电开机后,会与原先设置的开关相反,被打开或关闭(重启操作就正常) to 【H5PRO】【量产必解】【设置】【必现】在设置关闭按键音或者打开按键音,断电上电开机后,会与原先设置的开关相反,被打开或关闭(重启操作就正常)
- Priority changed from high priority to urgent
Updated by daquan huang 22 days ago
- Status changed from under verification to closed